PGFI Series
30 Amp Multi-Phase Portable Series (Cord) GFCI / ELCI
INTRODUCTION
The LineGard? 30 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North
Shore Safety, Ltd., a leader in innovated safety products.
Available with an operating voltage of 120/240 VAC, 3? 120/208 VAC, 3? 240 VAC (certified to CSA 22.2 only) or 3? 208 VAC, 3? 277
VAC (UL 1053 compliant). This product can be integrated during after-market equipment upgrades or used as a stand-alone portable
cordset. All units are MADE IN THE USA and are listed per UL 943 and CSA 22.2 No.144. Note that any power cord integrated with
this GFCI becomes OSHA compliant for portable power usage in confinded space: OSHA 29 CFR 1926.404 (b)(1)(ii) and OSHA 29 CFR
1926.405 (a)(2)(ii)(G). Additionally, these devices meet NEC requirement 590.6 (a) and (b).
FEATURES
SPECIFICATIONS
?  POWER AND FAULT STATUS INDICATORS
?  DOUBLE INSULATED USER INTERFACE
?  INDUSTRIAL DESIGN FOR ROUGH SERVICE
?  CHEMICAL AND UV RESISTANT ENCLOSURE
?  CULUS LISTED AS A CLASS A GFCI PER UL 943 AND
CSA 22.2 No. 144
?  30 AMP CONFIGURATIONS IN 120/240 VAC 4-WIRE,
3? 120/208 VAC 5-wire, 3? 240 VAC 4-wire,
3? 208 VAC 4-wire, 3? 277 VAC 4-wire (UL 1053)
?  NEMA 4X AND 6P WET LOCATION RATED (INDOOR / OUTDOOR)
?  AVAILABLE IN AUTOMATIC OR MANUAL RESET CONFIGURATIONS*
Listing Type
Rated Supply Voltage
Rated Current
Horse Power
Trip Level, Class A
Phase
Operating Frequency
Reset Type 1
Response Time
Operating Temperature
Operating Voltage Range
Let-Go Voltage
Open Neutral Protection
Grounded Neutral Protection
cULus Listed Class A
UL 943, UL 1053
CSA 22.2 No. 144
120/240 VAC, 3? 120/208 VAC,
3? 240 VAC (CSA only),
3? 208 VAC, 3? 277 VAC (UL 1053)
Up to 30 Amps or rating of wiring
device and/or cable
1HP @ 120 VAC, 3HP @ 240 VAC
5mA +/– 1mA
Dual voltage and 3 phase
60 Hz
Automatic or Manual
25mS max
–35°C to 66°C
85% to 110% of rated VAC
60% of supply voltage
Trips upon loss of neutral
Trips if ground and neutral touch
at load side
1. Manual configuration should be specified if automatic start-up after power
restoration of circuit power creates an unsafe condition.
276
PGFI Series - 30 Amp Multi-Phase Portable (Cord) Series
http://airpax.sensata.com/
相关PDF资料
PGFI-A040KYTT25 CORD GFCI 120VAC 25' YEL TRITAP
PGFP-A110KYTT25 CORD GFCI 120VAC 25' YEL TRITAP
PGFR-120 WALLPLUG GFCI 15/20A WHT 120V
PGFS-73005 MANUAL GFCI 30A 240VAC 18"
PHEC60RT-S210-M2LF PHEC60RT-S210-M2LF
PI2003-EVAL1 EVALUATION BOARD FOR PI2003
PI2007-EVAL2 EVAL BRD FOR PI2007 12V/15A
PI2126-EVAL1 EVALUATION BOARD FOR PI2126
相关代理商/技术参数
PGFI-A04 功能描述:PLUG GFCI 120VAC 15/20A AUTORST RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFI 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFI-A040KYST2 功能描述:CORD GFCI 120VAC 2' YEL SNG TAP RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFI 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFI-A040KYST25 功能描述:CORD GFCI 120VAC 25' YEL SNG RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFI 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFI-A040KY-ST25 制造商:Airpax 功能描述:
PGFI-A040KYTT2 功能描述:CORD GFCI 120VAC 2' YEL TRITAP RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFI 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFI-A040KYTT25 功能描述:CORD GFCI 120VAC 25' YEL TRITAP RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFI 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFI-M04 功能描述:PLUG GFCI 120VAC 15A MAN RST RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFI 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFI-M040KYST2 功能描述:CORD GFCI 120VAC 2' YEL SNG TAP RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFI 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041